Full Description

1.1 This procedure covers the determination of diisopropyl methylphosphonate (DIMP), ethyl hydrogen dimethylamidophosphate (EHDMAP), ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA), methylphosphonic acid (MPA) and pinacolyl methylphosphonic acid (PMPA) (referred to collectively as organophosphonates in this test method) in surface water by direct injection using liquid chromatography (LC) and detected with tandem mass spectrometry (MS/MS) using electrospray ionization (ESI). These analytes are qualitatively and quantitatively determined by this test method. This test method adheres to single reaction monitoring (SRM) mass spectrometry.
1.2 This test method has been developed by U.S. EPA Region 5 Chicago Regional Laboratory (CRL).
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 The detection verification level (DVL) and reporting range for the organophosphonates are listed in Table 1.
TABLE 1 Detection Verification Level and Reporting Range Analyte ESI Mode DVL (μg/L) Reporting Range (μg/L) Diisopropyl methylphosphonate Positive 1 5-150 Ethyl hydrogen dimethylamidophosphate Negative 0.25 5-150 Ethyl hydrogen dimethylamidophosphate Positive 0.25 5-150 Ethyl methylphosphonic acid Negative 5 50-1500 Ethyl methylphosphonic acid Positive 5 50-1500 Isopropyl methylphosphonic acid Negative 10 50-1500 Isopropyl Methylphosphonic acid Positive 5 50-1500 Methylphosphonic acid Negative 20 100-1500 Methylphosphonic acid Positive 10 50-1500 Pinacolyl methylphosphonic acid Negative 5 50-1500 Pinacolyl methylphosphonic acid Positive 5 50-1500
1.4.1 The DVL is required to be at a concentration at least three times below the reporting limit (RL) and have a signal/noise ratio greater than 3:1. Fig. 1 displays the signal/noise ratios at the DVLs for the organophosphonates in the ESI positive mode and Fig. 2 in the ESI negative mode.
FIG. 1 Example ESI Positive Mode SRM Chromatograms Signal/Noise Ratios
Example ESI Positive Mode SRM Chromatograms Signal/Noise
 RatiosExample ESI Positive Mode SRM Chromatograms Signal/Noise
 Ratios
FIG. 2 Example ESI Negative Mode SRM Chromatograms Signal/Noise Ratios
Example ESI Negative Mode SRM Chromatograms Signal/Noise
 RatiosExample ESI Negative Mode SRM Chromatograms Signal/Noise
 Ratios
1.4.2 The reporting limit is the concentration of the Level 1 calibration standard as shown in Table 2 for the organophosphonates except for MPA in the ESI negative mode which is at Level 2 due to not meeting the DVL criteria at the lower concentration level. The DVL for MPA in the ESI negative mode is at 20 μg/L, which forces a raised reporting limit. However, the multi-laboratory validation required a spike of all target analytes at Level 1 concentrations. The mean recovery for MPA in the ESI negative mode at this level was 98.7 % as shown in Table 3. If your instrument's sensitivity can meet the requirements in this test method, MPA may have a 50 μg/L reporting limit.
TABLE 2 Concentrations of Calibration Standards (PPB) Analyte/Surrogate LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 7 Diisopropyl methylphosphonate 5 10 20 35 50 100 150 Ethyl hydrogen dimethylamidophosphate 5 10 20 35 50 100 150 Ethyl methylphosphonic acid 50 100 200 350 500 1000 1500 Isopropyl methylphosphonic acid 50 100 200 350 500 1000 1500 Methylphosphonic acid 50 100 200 350 500 1000 1500 Pinacolyl methylphosphonic acid 50 100 200 350 500 1000 1500  

Product Details

Published:
06/15/2017
Number of Pages:
13
File Size:
1 file , 330 KB
Note:
This product is unavailable in Russia, Ukraine, Belarus
 

Document History

  1. ASTM D7597-16(2024)


    Standard Test Method for Determination of Diisopropyl Methylphosphonate, Ethyl Hydrogen Dimethylamidophosphate, Ethyl Methylphosphonic Acid, Isopropyl Methylphosphonic Acid, Methylphosphonic Acid and Pinacolyl Methylphosphonic Acid in Water by Liquid Chromatography/Tandem Mass Spectrometry

    • Most Recent
  2. ASTM D7597-16(2017)

    👀 currently
    viewing


    Standard Test Method for Determination of Diisopropyl Methylphosphonate, Ethyl Hydrogen Dimethylamidophosphate, Ethyl Methylphosphonic Acid, Isopropyl Methylphosphonic Acid, Methylphosphonic Acid and Pinacolyl Methylphosphonic Acid in Water by Liquid Chromatography/Tandem Mass Spectrometry

    • Historical Version
  3. ASTM D7597-16


    Standard Test Method for Determination of Diisopropyl Methylphosphonate, Ethyl Hydrogen Dimethylamidophosphate, Ethyl Methylphosphonic Acid, Isopropyl Methylphosphonic Acid, Methylphosphonic Acid and Pinacolyl Methylphosphonic Acid in Water by Liquid Chromatography/Tandem Mass Spectrometry

    • Historical Version
  4. ASTM D7597-09e2


    Standard Test Method for Determination of Diisopropyl Methylphosphonate, Ethyl Hydrogen Dimethylamidophosphate, Ethyl Methylphosphonic Acid, Isopropyl Methylphosphonic Acid, Methylphosphonic Acid and Pinacolyl Methylphosphonic Acid in Water by Liquid Chro

    • Historical Version
  5. ASTM D7597-09e1


    Standard Test Method for Determination of Diisopropyl Methylphosphonate, Ethyl Hydrogen Dimethylamidophosphate, Ethyl Methylphosphonic Acid, Isopropyl Methylphosphonic Acid, Methylphosphonic Acid and Pinacolyl Methylphosphonic Acid in Water by Liquid Chro

    • Historical Version
  6. ASTM D7597-09


    Standard Test Method for Determination of Diisopropyl Methylphosphonate, Ethyl Hydrogen Dimethylamidophosphate, Ethyl Methylphosphonic Acid, Isopropyl Methylphosphonic Acid, Methylphosphonic Acid and Pinacolyl Methylphosphonic Acid in Water by Liquid Chro

    • Historical Version

What is a Redline?

A redline document shows additions, deletions and other content and formatting changes between the active standard and the previous edition.

If you purchase a redline upgrade, you will receive TWO versions of the document – the current edition of the standard and the redline version.

How to Buy

To upgrade your document to include the redline version:

  • Add the document to your cart.
  • Select the Upgrade with Redline option in the cart pop up.
  • Click “Add Selected Upgrades” button to add the redline version to your cart.

What is a Multi-User PDF?

Multi-User PDF files allow you to purchase access to specific documents for use in your company for up to nine users.

How to Buy

To upgrade your PDF to a Multi-User version:

  • Add the PDF to your cart.
  • Select your desired number of users.
  • Click "Add Selected Upgrades" button to add the multi-user version of the PDF to your cart.

Upon completing your order, you’ll be prompted to enter the email addresses of the users who will need access to the PDF.

What is a Multi-User Redline PDF?

A redline Multi-User document gives you the both the ability to compare all the changes between the active standard and the previous version and to provide you with access for up to nine users.

Use Redlines To:

  • Identify updates in minutes, not hours
  • Effortlessly implement changes to procedures, equipment and products
  • Save time and resources
  • When you purchase Techstreet redlines, you receive TWO documents -- the clean, active version of the standard and the redline version.

Use Multi-User PDFs To:

  • Save money when you buy a document for your team
  • Save time by purchasing once for multiple users
  • Effortlessly distribute a PDF to your team with our self-service interface

How to Buy

  • To upgrade your PDF to a Multi-User Redline version, simply add the PDF to your cart and you will be presented with a pop-up window that will display user and pricing information.
  • From the pop-up window, select your upgrade and press the “Add Selected Upgrades” button.

There are corrections to this edition, which are available as separate documents.

There are amendments to this edition, which are available as separate documents.

Techstreet's Printed Edition + PDF option allows you to purchase a print edition of your document along with a PDF for immediate download at a package price.

This is a historical version of this document. A more current edition is available.

This is the most up-to-date edition of this document.

A secure PDF contains features that enforce existing copyright laws by preventing reproduction or distribution to other users. In order to successfully use your secure PDF, Adobe Acrobat Reader 8.0 or higher, and the free FileOpen plug-in installed.

Device/OS: Unknown
Browser: Unknown Browser 0.0
User Agent: Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; [email protected])
Store Name: amca
Page: /amca/standards/astm-d7597-16-2017?product_id=2903196
Referrer: Direct Navigation
IP: 3.144.112.74, 172.68.168.239
Language: en
Customer #: Not Logged In
Member?: YES
Cart #: 1241781392
Order #: None
Cookies: YES
×