Available Formats
- Availability
- Priced From ( in USD )
-
Available Formats
-
- Immediate download
- $69.60
- Add to Cart
-
- Printed Edition
- Ships in 1-2 business days
- $69.60
- Add to Cart
Customers Who Bought This Also Bought
-
ASTM E116-97
Priced From $78.00 -
ASTM E247-21
Priced From $57.60 -
ASTM E572-21
Priced From $69.60 -
ASTM E246-21
Priced From $64.80
About This Item
Full Description
1.1 This test method covers the wavelength dispersive X-ray spectrometric analysis of low-alloy steels for the following elements:
Element | Concentration Range, % |
Nickel | 0.04 to 3.0 |
Chromium | 0.04 to 2.5 |
Manganese | 0.04 to 2.5 |
Silicon | 0.06 to 1.5 |
Molybdenum | 0.005 to 1.5 |
Copper | 0.03 to 0.6 |
Vanadium | 0.012 to 0.6 |
Cobalt | 0.03 to 0.2 |
Sulfur | 0.009 to 0.1 |
Niobium | 0.002 to 0.1 |
Phosphorus | 0.010 to 0.08 |
Calcium | 0.001 to 0.007 |
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 10.
Document History
-
ASTM E1085-22
Standard Test Method for Analysis of Low-Alloy Steels by Wavelength Dispersive X-Ray Fluorescence Spectrometry- Most Recent
-
ASTM E1085-16
Standard Test Method for Analysis of Low-Alloy Steels by Wavelength Dispersive X-Ray Fluorescence Spectrometry- Historical Version
-
ASTM E1085-09
Standard Test Method for Analysis of Low-Alloy Steels by X-Ray Fluorescence Spectrometry- Historical Version
-
ASTM E1085-95(2004)e1
viewing
Standard Test Method for X-Ray Emission Spectrometric Analysis of Low-Alloy Steels- Historical Version
-
ASTM E1085-95(2004)
Standard Test Method for X-Ray Emission Spectrometric Analysis of Low-Alloy Steels- Historical Version
-
ASTM E1085-95(2000)
Standard Test Method for X-Ray Emission Spectrometric Analysis of Low-Alloy Steels- Historical Version