This item is not available for sale.

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

ADOPTED_FROM:EN 1196:1998 This standard specifies the additional requirements and test methods for gas-fired air heaters which are so designed that water vapour condenses from combustion products. On this subject it extends the European standards EN 778 and EN 1319 for domestic, and EN 621 and EN 1020 for non-domestic air heaters. This standard applies to gas-fired air heaters with or without a fan in the combustion circuit in one of the following constructional types: - an integral air heater with at least one condensing heat exchanger; - a non-condensing air heater with an integrated additional condensing heat exchanger; - a non-condensing air heater, with an integrated additional condensing heat exchanger for the recovery of heat from combustion products and from ventilation air if appropriate. This European Standard covers type-testing only.
 

Document History

  1. NS-EN 17082:2019


    Domestic and non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW

    • Most Recent
  2. NS-EN 1196:2011


    Domestic and non-domestic gas-fired air heaters — Supplementary requirements for condensing air heaters

    • Historical Version
  3. NS-EN 1319:2009


    Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW

    • Historical Version
  4. NS-EN 621:2009


    Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products

    • Historical Version
  5. NS-EN 778:2009


    Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 70 kW, without a fan to assist transportation of combustion air and/or combustion products

    • Historical Version
  6. NS-EN 1020:2009


    Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products

    • Historical Version
  7. NS-EN 525:2009


    Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW

    • Historical Version
  8. NS-EN 621:1998/A1:2001


    Amendment A1 — Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products

    • Historical Version
  9. NS-EN 1319:1998/A1:2001


    Amendment A1 — Domestic gas-fired forced convection air heaters for space heating with fan-assisted burners not exceeding a net heat input of 70 kW

    • Historical Version
  10. NS-EN 778:1998/A1:2001


    Amendment A1 — Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 70 kW, without a fan to assist transportation of combustion air and/or combustion products

    • Historical Version
  11. NS-EN 1020:1997/A1:2001


    Amendment A1 — Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, incorporating a fan to assist transportation of combustion air and/or combustion products

    • Historical Version
  12. NS-EN 1319:1998/A2:1999


    Amendment A2 — Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW

    • Historical Version
  13. NS-EN 1196:1998

    👀 currently
    viewing


    Domestic and non-domestic gas-fired air heaters — Supplementary requirements for condensing air heaters

    • Historical Version
  14. NS-EN 1319:1998


    Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW

    • Historical Version
  15. NS-EN 621:1998


    Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products

    • Historical Version
  16. NS-EN 778:1998


    Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 70 kW, without a fan to assist transportation of combustion air and/or combustion products

    • Historical Version
  17. NS-EN 525:1997


    Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW

    • Historical Version
  18. NS-EN 1020:1997


    Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, incorporating a fan to assist transportation of combustion air and/or combustion products

    • Historical Version