Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
    • Printed Edition
    • Ships in 1-2 business days
    • $333.60
    • Add to Cart
    • Printed Edition + PDF
    • Immediate download
    • $550.80
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

NOTE 1: There is guidance or rationale for this subclause contained in Clause AA.2.

This document applies to the basic safety and essential performance of ventilatory support equipment, as defined in 201.3.302, for ventilatory impairment, as defined in 201.3.300, hereafter also referred to as ME equipment, in combination with its accessories:
— intended for use in the home healthcare environment;

NOTE 2: In the home healthcare environment, the supply mains driving the ventilatory support equipment is often not reliable.

NOTE 3: Such ventilatory support equipment can also be used in professional health care facilities.

— intended for use by a lay operator;
— intended for use with patients who have ventilatory impairment, the most fragile of these patients, would not likely experience injury with the loss of this artificial ventilation; and
— not intended for patients who are dependent on artificial ventilation for their immediate life support.

EXAMPLE 1: Patients with mild to moderate chronic obstructive pulmonary disease (COPD).

Ventilatory support equipment is not considered to use a physiologic closed-loop control system unless it uses a physiological patient variable to adjust the artificial ventilation therapy settings.

This document is also applicable to those accessories intended by their manufacturer to be connected to the
breathing system of ventilatory support equipment for ventilatory impairment, where the characteristics of those accessories can affect the basic safety or essential performance of the ventilatory support equipment for ventilatory impairment.

EXAMPLE 2: Breathing sets, connectors, water traps, expiratory valve, humidifier, breathing system filter, external electrical power source, distributed alarm system.

If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant.

Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005+AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1.

NOTE 4: Additional information can be found in IEC 60601-1:2005+AMD1:2012+AMD2:2020, 4.2.

NOTE 5: See ISO/TR 21954 for guidance on the selection of the appropriate ventilator for a given patient.
 

Document History

  1. ISO 80601-2-79:2024

    👀 currently
    viewing


    Medical electrical equipment - Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment

    • Most Recent
  2. ISO 80601-2-79:2018


    Medical electrical equipment - Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment

    • Historical Version
  3. ISO 10651-6:2004


    Lung ventilators for medical use - Particular requirements for basic safety and essential performance - Part 6: Home-care ventilatory support devices

    • Historical Version