-
-
Available Formats
- Options
- Availability
- Priced From ( in USD )
-
Available Formats
-
- Immediate download
-
$132.00Members pay $99.00
- Add to Cart
-
- Printed Edition
- Ships in 1-2 business days
-
$132.00Members pay $99.00
- Add to Cart
-
- Printed Edition + PDF
- Immediate download
-
$191.00Members pay $144.00
- Add to Cart
Customers Who Bought This Also Bought
-
Standard 62.1 Calculators
Priced From $39.00 -
ASHRAE 102-1983 (RA 89)
Priced From $33.00 -
ASHRAE 173-2012 (RA 2016)
Priced From $75.00 -
ASHRAE 33-2016
Priced From $66.00
About This Item
Full Description
First published in 1973as Standard 62, Standard 62.1 specifies minimum ventilation rates and othermeasures for new and existing buildings that are intended to provide indoor airquality that is acceptable to human occupants and that minimizes adverse healtheffects.
The revised 2019 edition of the standardincludes significant changes, including:
- New informative tables of ventilation rates per unit areafor checking new and existing buildings ventilation calculations
- Simplified version of the Ventilation Rate Procedureimproving calculations for system ventilation efficiency and zone airdistribution effectiveness
- Modified Natural Ventilation Procedure calculationmethodology
- Revised scope to specifically identify occupanciespreviously not covered
Additionally:
- Natural ventilation now requires considering the quality ofthe outdoor air and interaction of the outdoor air with mechanically cooledspaces.
- Humidity control requirements are now expressed as dew pointand not as relative humidity.
Document History
-
ASHRAE 62.1-2022
Standard 62.1-2022 -- Ventilation and Acceptable Indoor Air Quality (ANSI Approved)- Most Recent
-
ASHRAE 62.1-2019
viewing
Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved)- Historical Version
-
ASHRAE 62.1-2016
Standard 62.1-2016 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved)- Historical Version
-
ASHRAE 62.1-2013
Standard 62.1-2013 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved)- Historical Version
-
ASHRAE 62.1-2010
Standard 62.1-2010 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved)- Historical Version
-
ASHRAE 62.1-2007
Standard 62.1-2007 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved)- Historical Version
-
ASHRAE 62.1-2004
Standard 62.1-2004 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved)- Historical Version
-
ASHRAE 62-2001
Standard 62-2001 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved)- Historical Version
-
ASHRAE 62-1999
Standard 62-1999 -- Ventilation for Acceptable Indoor Air Quality- Historical Version
-
ASHRAE 62-1989
Standard 62-1989 -- Ventilation for Acceptable Indoor Air Quality- Historical Version
-
ASHRAE 62-1981
Standard 62-1981 -- Ventilation for Acceptable Indoor Air Quality- Historical Version
-
ASHRAE 62-73
Standard 62-73 -- Standards for Natural and Mechanical Ventilation- Historical Version
Amendments, rulings, supplements, and errata
-
ASHRAE IC 62.1-2019-4
Download
Interpretation IC 62.1-2019-4 of Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE IC 62.1-2019-3
Download
Interpretation IC 62.1-2019-3 of Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE 62.1-2019 Addendum i
Download
Addendum i to Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE 62.1-2019 Addendum aa
Download
Addendum aa to Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE 62.1-2019 Addendum g
Download
Addendum g to Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE 62.1-2019 Addendum f
Download
Addendum f to Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE 62.1-2019 Errata (June 15, 2021)
Download
Errata to Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE IC 62.1-2019-2
Download
Interpretation IC 62.1-2019-2 of Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE IC 62.1-2019-1
Download
Interpretation IC 62.1-2019-1 of Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE 62.1-2019 Errata (December 1, 2020)
Download
Errata to Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE 62.1-2019 Addendum b
Download
Addendum b to Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE 62.1-2019 Errata (June 1, 2020)
Download
Errata to Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE 62.1-2019 Errata (April 17, 2020)
Download
Errata to Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE 62.1-2019 Addendum p
Download
Addendum p to Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE 62.1-2019 Addendum y
Download
Addendum y to Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved) -
ASHRAE 62.1-2019 Addendum ao
Download
Addendum ao to Standard 62.1-2019 -- Ventilation for Acceptable Indoor Air Quality (ANSI Approved)