About This Item
Full Description
The goal of our work is to improve uncertainty estimates and test protocols starting from model scale experiments in controlled laboratory conditions. We first present the experimental facility we developed to perform pressurization tests at model scale, which includes: 1- a model at 1/25th, 2- a pressurization device that pressurizes the model up to 100 Pa and 3- a wind tunnel in which the wind is stable from 0 to 7 m s-1. Secondly, we present the zero-flow pressure measurement results for 9 leakage distributions and 8 wind speeds: these results strongly depends on the leakage disbritbution, with an abdsolute value of zero-flow pressure difference that varies for strong winds from 1 Pa to more than 16 Pa. Finally, we calculate the error due to steady wind from 96 tests performed according to ISO 9972 in various wind conditions and for the 9 leakage distributions. At 4 Pa, the maximal error varies from 2% to 35%.
Citation: IAQ 2020: Indoor Environmental Quality