Language:
    • Available Formats
    •  
    • Availability
    • Priced From ( in USD )
    • Printed Edition
    • Ships in 1-2 business days
    • $129.00
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

IEC 60364-5-52:2009 deals with the selection and erection of wiring systems. This third edition cancels and replaces the second edition, published in 2001, and constitutes a technical revision. The main changes with respect to the previous edition are as follows: – Subclause 521.4 introduces minor changes with regard to busbar trunking systems and powertrack systems. – Subclause 523.6 introduces minor changes with regard to the sizing of cables where harmonic currents are present. – A new sublause 523.9 concerning single-core cables with a metallic covering has been introduced. – Clause 525 introduces changes in the maximum value of voltage drop permitted between the origin of the consumer's installation and the equipment which should not be greater than that given in the relevant annex. – Clause 526 introduces minor changes to electrical connections including additional exceptions for inspection of connections and additional notes. – Clause 528 introduces additional requirements with regard to proximity of underground power and telecommunication cables. – Clause 529 introduces minor changes to selection and erection of wiring systems in relation to maintainability, including cleaning.

 

Document History

  1. DANSK DSF/FPRHD 60364-5-52


    Low-voltage electrical installations -- Part 5-52: Selection and erection of electrical equipment - Wiring systems

    • Historical Version
  2. DANSK DSF/FPRHD 60364-5-52/FPRAA


    Low-voltage electrical installations -- Part 5-52: Selection and erection of electrical equipment - Wiring systems

    • Historical Version
  3. DANSK DSF/FPRHD 60364-5-52/FPRAA


    Low-voltage electrical installations -- Part 5-52: Selection and erection of electrical equipment - Wiring systems

    • Historical Version
  4. DANSK DSF/HD 60364-5-52/PRAB


    Low-voltage electrical installations – Part 5-52: Selection and erection of electrical equipment – Wiring systems

    • Historical Version
  5. DANSK DSF/HD 60364-5-52/FPRAB


    Low-voltage electrical installations – Part 5-52: Selection and erection of electrical equipment – Wiring systems

    • Historical Version
  6. DANSK DSF/FPRHD 60364-5-52


    Low-voltage electrical installations -- Part 5-52: Selection and erection of electrical equipment - Wiring systems

    • Historical Version
  7. DANSK DS/HD 60364-5-52

    👀 currently
    viewing


    Low-voltage electrical installations – Part 5-52: Selection and erection of electrical equipment – Wiring systems

    • Most Recent
 

Amendments, rulings, supplements, and errata

  1. DANSK DS/HD 60364-5-52+A11+RET.1+TILL.1+RET.2+A12+RET.3 (SIK)


    Elektriske lavspændingsinstallationer – Del 5-52: Valg og installation af elektrisk materiel – Ledningssystemer

  2. DANSK DS/HD 60364-5-52+A11/RET. 1 (SIK)


    Elektriske lavspændingsinstallationer – Del 5-52: Valg og installation af elektrisk materiel – Ledningssystemer

  3. DANSK DS/HD 60364-5-52+A11+RET.1+TILL. 1 (SIK)


    Elektriske lavspændingsinstallationer – Del 5-52: Valg og installation af elektrisk materiel – Ledningssystemer

  4. DANSK DS/HD 60364-5-52+A11+RET.1+TILL.1+RET.2+A12 (SIK)


    Elektriske lavspændingsinstallationer – Del 5-52: Valg og installation af elektrisk materiel – Ledningssystemer

  5. DANSK DS/HD 60364-5-52+A11 (SIK)


    Elektriske lavspændingsinstallationer – Del 5-52: Valg og installation af elektrisk materiel – Ledningssystemer

  6. DANSK DS/HD 60364-5-52+A11+RET.1+TILL.1+RET.2 (SIK)


    Elektriske lavspændingsinstallationer – Del 5-52: Valg og installation af elektrisk materiel – Ledningssystemer

  7. DANSK DS/HD 60364-5-52+A11+RET. 1/TILL. 1 (SIK)


    Elektriske lavspændingsinstallationer – Del 5-52: Valg og installation af elektrisk materiel – Ledningssystemer

  8. DANSK DS/HD 60364-5-52 (SIK)


    Elektriske lavspændingsinstallationer – Del 5-52: Valg og installation af elektrisk materiel – Ledningssystemer

  9. DANSK DS/HD 60364-5-52/A11


    Low-voltage electrical installations – Part 5-52: Selection and erection of electrical equipment – Wiring systems

  10. DANSK DS/HD 60364-5-52+A11+RET.1+TILL.1+RET.2+A12/RET.3 (SIK)


    Elektriske lavspændingsinstallationer – Del 5-52: Valg og installation af elektrisk materiel – Ledningssystemer – RETTELSER 3

  11. DANSK DS/HD 60364-5-52/A12


    Low-voltage electrical installations – Part 5-52: Selection and erection of electrical equipment – Wiring systems

  12. DANSK DS/HD 60364-5-52+A11+RET.1+TILL.1/RET.2 (SIK)


    Elektriske lavspændingsinstallationer – Del 5-52: Valg og installation af elektrisk materiel – Ledningssystemer – RETTELSER 2

  13. DANSK DS/HD 60364-5-52+A11+RET. 1 (SIK)


    Elektriske lavspændingsinstallationer – Del 5-52: Valg og installation af elektrisk materiel – Ledningssystemer