    • P63332-387/FDIS, Apr 2024 - UNAPPROVED DRAFT
    • $88.00
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

Scope

The alternating current (AC) power supply system performs a key safety function at nuclear facilities. The safety classified electric power system is essential for mitigating the consequences of accidents at facilities and preventing significant release of radioactive material to the environment. An onsite AC power source is required for supporting the safe shutdown of the facility in the event of loss of power from the external offsite sources. At nuclear power plants, the standby AC power source must be capable of providing the capacity and capability to assure that fuel design limits and design conditions of the reactor coolant pressure boundary are not exceeded for any anticipated occurrences, and the core is cooled and containment integrity and other vital functions are maintained in the event of postulated accidents. This requires the establishment of a reliable and robust power supply system that can be used to mitigate the consequences of postulated accident conditions. Important provisions in meeting this requirement are the principal design criteria, the design features, testing, and qualification requirements of the standby AC power source. Most nuclear power plants use diesel generators as standby AC power sources. This standard defines the requirements for the design of a robust standby AC power source that can be routinely tested to demonstrate operational capacity and capability. The standard provides design and testing requirements to demonstrate continuous load carrying capability and resilience to large load perturbations to ensure that diesel generators, used as standby AC power sources, have sufficient capacity, capability, and reliability to perform their intended function.

Purpose

The on-site AC interruptible electrical power system supports all nuclear facility operating functions including the safety systems. The purpose of this standard is to provide recommendations for the design and testing requirements of on-site standby AC electrical power sources used for safely shutting down and maintaining safe shutdown conditions at nuclear facilities following loss of power from the offsite transmission network. The standard also defines the requirements for diesel generators used as standby AC power sources at nuclear power plants. The standard provides the principal design criteria, the design features, testing, and qualification requirements for the individual diesel-generator units that enable them to meet their functional requirements as a part of the standby power source under the conditions produced by the design basis events cataloged in the plant safety analysis.

Abstract

Revision Standard - Active - Draft.