DIN EN ISO 3743-1
Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering methods for small, movable sources in reverberant fields - Part 1: Comparison method for a hard-walled test room (ISO 3743-1:2010)- This is the most recent version of this document.
-
BS EN ISO 3743-1:2010
Acoustics. Determination of sound power levels and sound energy levels of noise sources using sound pressure. Engineering methods for small movable sources in reverberant fields-Comparison method for a hard-walled test room- This is the most recent version of this document.
About This Item
Full Description
ISO 3743-1:2010 specifies methods for determining the sound power level or sound energy level of a noise source by comparing measured sound pressure levels emitted by this source (machinery or equipment) mounted in a hard-walled test room, the characteristics of which are specified, with those from a calibrated reference sound source. The sound power level (or, in the case of noise bursts or transient noise emission, the sound energy level) produced by the noise source, in frequency bands of width one octave, is calculated using those measurements. The sound power level or sound energy level with frequency A-weighting applied is calculated using the octave-band levels.
The method specified in ISO 3743-1:2010 is suitable for all types of noise (steady, non-steady, fluctuating, isolated bursts of sound energy, etc.) defined in ISO 12001.
The noise source under test may be a device, machine, component or sub-assembly. The maximum size of the source depends upon the size of the room used for the acoustical measurements (see 4.2).
The test environment that is applicable for measurements made in accordance with ISO 3743-1:2010 is a hard-walled test room with prescribed acoustical characteristics.
Information is given on the uncertainty of the sound power levels and sound energy levels determined in accordance with ISO 3743-1:2010, for measurements made in frequency octave bands and for A-weighted frequency calculations performed on them. The uncertainty conforms to ISO 12001:1996, accuracy grade 2 (engineering grade).
Document History
-
ISO 3743-1:2010
viewing
Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering methods for small movable sources in reverberant fields - Part 1: Comparison method for a hard-walled test room- Most Recent
-
ISO 3743-1:1994
Acoustics - Determination of sound power levels of noise sources - Engineering methods for small, movable sources in reverberant fields - Part 1: Comparison method for hard-walled test rooms- Historical Version