-
-
Available Formats
- Options
- Availability
- Priced From ( in USD )
-
Available Formats
-
- Immediate download
- $417.00
- Add to Cart
-
- Printed Edition
- Ships in 1-2 business days
- $480.00
- Add to Cart
-
- Printed Edition + PDF
- Immediate download
- $688.00
- Add to Cart
Customers Who Bought This Also Bought
-
CISPR 24 Ed. 2.0 b:2010
Priced From $281.00 -
CISPR 16-1-2 Ed. 2.1 b:2017
Priced From $658.00 -
IEC/TR 61000-4-1 Ed. 1.0 en:2016
Priced From $145.00 -
IEC 61326-2-3 Ed. 3.0 b:2020
Priced From $190.00
About This Item
Full Description
This part of IEC 61000 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz.
NOTE 1 Product committees might decide to use the methods described in this document also for frequencies up to 230 MHz (see Annex B) although the methods and test instrumentation are intended to be used in the frequency range up to 80 MHz.
Equipment not having at least one conducting wire or cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded from the scope of this document.
NOTE 2 Test methods are specified in this part of IEC 61000 to assess the effect that conducted disturbing signals, induced by electromagnetic radiation, have on the equipment concerned. The simulation and measurement of these conducted disturbances are not adequately exact for the quantitative determination of effects. The test methods specified are structured for the primary objective of establishing adequate repeatability of results at various facilities for quantitative analysis of effects.
The object of this document is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by RF fields. The test method in this document describes a consistent method to assess the immunity of an equipment or system against a specified phenomenon.
NOTE 3 As described in IEC Guide 107, this document is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria.
Document History
-
IEC 61000-4-6 Ed. 5.0 b:2023
viewing
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields- Most Recent
-
IEC 61000-4-6 Ed. 5.0 en:2023
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields- Historical Version
-
IEC 61000-4-6 Ed. 4.0 b:2013
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields- Historical Version
-
IEC 61000-4-6 Ed. 3.0 b:2008
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields- Historical Version
-
IEC 61000-4-6 Ed. 2.2 b:2006
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields CONSOLIDATED EDITION- Historical Version
-
IEC 61000-4-6 Ed. 2.1 b:2004
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields CONSOLIDATED EDITION- Historical Version