Available Formats
- Options
- Availability
- Priced From ( in USD )
-
Available Formats
-
- Secure PDF 🔒
- Immediate download
- $187.20
- Add to Cart
-
- Softcover
- Ships in 3-5 business days
- $187.20
- Add to Cart
Customers Who Bought This Also Bought
-
ICC IFGC-2024
Priced From $140.40 -
ICC IMC-2024
Priced From $140.40 -
ICC IZC-2024
Priced From $64.50 -
ICC IFC-2024
Priced From $183.60
About This Item
Full Description
- Puzzle rooms (escape rooms) are now defined and regulated as special amusement areas, requiring compliance with Section 411 and special means of egress requirements.
- For the purposes of determining the allowable number of control areas in a building, each portion separated by one or more fire walls is now considered as a separate building.
- In Group E occupancies, enhanced classroom acoustics in compliance with ICC A117.1 are to be provided in all classrooms having of volume of 20,000 cubic feet or less.
- The requirements for metal composite materials and systems (MCM) installed on the exterior walls of Types I, II, III and IV construction were simplified and sprinkler allowances were deleted
- The use of intermodal shipping containers as buildings is now specifically addressed through provisions intended to supplement existing applicable IBC requirements.
- Automatic sprinkler protection is now required in Group S-2 open parking garages where any fire area exceeds 48,000 square feet.
- The 2017 edition of ICC A117.1 was adopted.
- Parapets of a minimum height are now required for aggregate-surfaced roofs to prevent blow-off.
- Mixed occupancy buildings with assembly spaces are placed in Risk Category III when the total public assembly occupant load is greater than 2500 people.
- The 2021 IBC snow map is updated to match ASCE 7-16 snow maps by adding a reference to ASCE 7 snow tables in states with large case study areas.
- Secondary rain loads are updated to be consistent with ASCE 7.
- Special inspection requirements were added to address the anchorage and connection of mass timber structural elements.
- Installation of firestop, fire-resistant joint systems and perimeter fire barrier systems in residential-use buildings now requires special inspection in Group R fire areas having an occupant load exceeding 250 people.
- Frost protection for egress doors was added to the foundation requirements.
- ACI standards ACI 117 and ITG 7 were added by reference to provide acceptable tolerances for concrete construction.
- Three new types of construction (Types IV-A, IV-B, and IV-C) allow mass timber buildings of taller heights, more stories above grade, and greater allowable areas compared to existing provisions for heavy timber buildings.
Document History
-
ICC IBC-2024
2024 International Building Code- Most Recent
-
ICC IBC-2021
viewing
2021 International Building Code- Historical Version
-
ICC IBC-2018
2018 International Building Code- Historical Version
-
ICC IBC-2015
2015 International Building Code- Historical Version
-
ICC IBC-2012
2012 International Building Code- Historical Version
-
ICC NY-BC-2010
Building Code of New York State, 2010- Historical Version
-
ICC IBC-2009
2009 International Building Code- Historical Version
-
ICC NY-BC-2007
Building Code of New York State, 2007- Historical Version
-
ICC IBC-2006
2006 International Building Code- Historical Version
-
ICC IBC-2003
2003 International Building Code- Historical Version
-
ICC IBC-2000
International Building Code- Historical Version