Language:
    • Available Formats
    •  
    • Availability
    • Priced From ( in USD )
    • Printed Edition
    • Ships in 1-2 business days
    • $65.00
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

a. This series of manuals, entitled Designing Facilities to Resist Nuclear Weapon Effects, is organized as follows:

TM 5-858-1 Facilities System Engineering

TM 5-858-2 Weapon Effects

TM 5-858-3 Structures

TM 5-858-4 Shock Isolation Systems

TM 5-858-5 Air Entrainment, Fasteners,

Penetration Protection,

Hydraulic-Surge Protective

Devices, EMP Protective

Devices

TM 5-858-6 Hardness Verification

TM 5-858-7 Facility Support Systems

TM 5-858-8 Illustrative Examples

A list of references pertinent to each manual is placed in an appendix. Additional appendixes and bibliographies are used, as required, for documentation of supporting information. Pertinent bibliographic material is identified in the text with the author's name placed in parentheses. Such bibliographic material is not necessary for the use of this manual; the name and source of publications related to the subject of this manual is provided for information purposes.

b. The purpose of this series of manuals is to provide guidance to engineers engaged in designing facilities that are required to resist nuclear weapon effects. It has been written for systems, structural, mechanical, electrical, and test engineers possessing state-of-the-art expertise in their respective disciplines, but having little knowledge of nuclear weapon effects on facilities. While it is applicable as general design guidelines to all Corps of Engineers specialists who participate in designing permanent military facilities, it has been written and organized on the assumption a systems-engineering group will coordinate design of the facilities.

c. Technical Manual 5-858 addresses only the designing of hardened facilities; other techniques to achieve survival capacity against nuclear weapon attacks are deception, duplication, dispersion, nomadization, reconstitution, and active defense. A facility is said to be hardened if it has been designed to directly resist and mitigate the weapon effects. Most of the hardening requirements are allocated to the subsidiary facilities, which house, support, and protect the prime mission materiel/personnel (PMMP). This manual is applicable to permanent facilities, such as those associated with weapon systems, materiel stockpiles, command centers, manufacturing centers, and communications centers.