1.1 This practice covers an analytical procedure for determining the transmissivity and storage coefficient of a confined aquifer taking into consideration the change in storage of water in overlying or underlying confining beds, or both. This practice is used to analyze water-level or head data collected from one or more observation wells or piezometers during the pumping of water from a control well at a constant rate. With appropriate changes in sign, this practice also can be used to analyze the effects of injecting water into a control well at a constant rate.

1.2 This analytical procedure is used in conjunction with Test Method D4050.

1.3 Limitations-The valid use of the modified Hantush method (1)2 is limited to the determination of hydraulic properties for aquifers in hydrogeologic settings with reasonable correspondence to the assumptions of the Hantush-Jacob method (Practice D6029/D6029M) with the exception that in this case the gain or loss of water in storage in the confining beds is taken into consideration (see 5.1). All possible combinations of impermeable beds and source beds (for example, beds in which the head remains uniform) are considered on the distal side of the leaky beds that confine the aquifer of interest (see Fig. 1).

FIG. 1 Cross Sections Through Discharging Wells in Leaky Aquifers with Storage of Water in the Confining Beds, Illustrating Three Different Cases of Boundary Conditions (from Reed (2) )

 Cross Sections Through Discharging Wells in Leaky
 Aquifers with Storage of Water in the Confining Beds, Illustrating
 Three Different Cases of Boundary Conditions (from Reed () )  Cross Sections Through Discharging Wells in Leaky
 Aquifers with Storage of Water in the Confining Beds, Illustrating
 Three Different Cases of Boundary Conditions (from Reed () )

1.4 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026.

1.4.1 The procedures used to specify how data are collected/recorded and calculated in the standard are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user's objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of these test methods to consider significant digits used in analysis methods for engineering data.

1.5 The values stated in SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values for the two systems may result in nonconformance with the standard. Reporting of results in units other than SI shall not be regarded as nonconformance with this standard.

1.6 This practice offers a set of instructions for performing one or more specific operations. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of the practice may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without the consideration of a project's many unique aspects. The word “Standard” in the title of this document means only that the document has been approved through the ASTM consensus process.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 

Document History

  1. ASTM D6028/D6028M-20

    👀 currently
    viewing


    Standard Practice for (Analytical Procedure) Determining Hydraulic Properties of a Confined Aquifer Taking into Consideration Storage of Water in Leaky Confining Beds by Modified Hantush Method

    • Most Recent
  2. ASTM D6028-17


    Standard Test Method (Analytical Procedure) for Determining Hydraulic Properties of a Confined Aquifer Taking into Consideration Storage of Water in Leaky Confining Beds by Modified Hantush Method

    • Historical Version
  3. ASTM D6028-96(2010)e1


    Standard Test Method (Analytical Procedure) for Determining Hydraulic Properties of a Confined Aquifer Taking into Consideration Storage of Water in Leaky Confining Beds by Modified Hantush Method

    • Historical Version
  4. ASTM D6028-96(2004)


    Standard Test Method (Analytical Procedure) for Determining Hydraulic Properties of a Confined Aquifer Taking into Consideration Storage of Water in Leaky Confining Beds by Modified Hantush Method

    • Historical Version
  5. ASTM D6028-96


    Standard Test Method (Analytical Procedure) for Determining Hydraulic Properties of a Confined Aquifer Taking into Consideration Storage of Water in Leaky Confining Beds by Modified Hantush Method

    • Historical Version