1.1 This practice covers procedures for testing installed non-perforated, gasketed corrugated high-density polyethylene (HDPE) pipelines using either water infiltration or exfiltration acceptance limits to demonstrate the integrity via the level of leakage of the installed materials, construction procedures and installation quality via the level of leakage. Pipe to be tested under this practice shall include corrugated HDPE drainage pipe meeting the requirements of AASHTO M 252, AASHTO M 294 and Specification F 2306/F 2306M.

Note 1

The performance criteria specified in this standard may be used for other plastic pipe products. The engineer, however, must assess if the testing procedures are adequate for the particular material and installation being considered.

Note 2

The user of this practice is advised that test criteria presented in this practice are similar to those in general use. Pipe, 600-mm (24-in.) diameter or larger, may be accepted by visual inspection when testing for infiltration.

1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are mathematical conversions to inch-pounds, which are provided for informational purposes only and are not considered standard.

1.3 This test method shall be performed on lines after all connections and service laterals have been plugged and braced adequately to withstand the test pressures. The time between completion of the backfill operations and testing shall be specified by the approving authority.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. The testing required under this standard necessitates operating in confined spaces. The user must insure that all OSHA and local safety codes are duly observed.

 

Document History

  1. ASTM F2487-21


    Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene and Polypropylene Pipelines

    • Most Recent
  2. ASTM F2487-13(2017)


    Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene and Polypropylene Pipelines

    • Historical Version
  3. ASTM F2487-13


    Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene and Polypropylene Pipelines

    • Historical Version
  4. ASTM F2487-06(2012)


    Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene Pipelines

    • Historical Version
  5. ASTM F2487-06

    👀 currently
    viewing


    Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene Pipelines

    • Historical Version