Full Description

BS 7870-4.20:2011+A1:2016 specifies requirements for the construction, dimensions and mechanical and electrical properties of 6.35/11(12) kV three-core cables having either aluminium or copper conductors, cross-linked polyethylene (XLPE) or ethylene propylene rubber (EPR) extruded insulation, a copper wire metallic screen and an oversheath of one of the following compounds.
  • medium density polyethylene (MDPE) compound type DMP 5 (Type A cables);
  • thermoplastic compound type DMZ 4 for cables having a low emission of smoke and corrosive gases when affected by fire (Type B cables).
This section of BS 7870 is applicable to cables that are designed for a maximum continuous conductor operating temperature of 90 °C and for a maximum short-circuit conductor temperature of 250 °C.
NOTE Information to be supplied by the purchaser, and items to be agreed between the purchaser and the manufacturer at the time of enquiry and/or order are given in Annex B. Guidance on type testing is given in Annex C.

To be read in conjunction with BS 7870-1:2011,BS 7870-2:2011


Cross References:
BS 3988:1970+A3:1989
BS 7870-1
BS 7870-2
BS EN 50267-2-1
BS EN 60228:2005
BS EN 60332-1-2:2004
BS EN 60332-3-24:2009
BS EN 60811-1-2
BS EN 60811-1-3
BS EN 60811-2-1
BS EN 61034-1
BS EN 61034-2
HD 603 S1
HD 605 S2
HD 620 S2
HD 626 S1
HD 627 S1
IEC 60502-2


Incorporates the following:
Corrigendum, August 2012. Amendment, June 2016. Amends and replaces BS 7870-4 .20:2011
 

Document History

  1. BS 7870-4.20:2011+A1:2016

    👀 currently
    viewing


    LV and MV polymeric insulated cables for use by distribution and generation utilities-Specification for distribution cables with extruded insulation for rated voltages of 11 kV to 33 kV-Three-core 11 kV cables (Implementation of HD 620)

    • Most Recent
  2. BS 7870-4.20:2011


    LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV to 33 kV. Three-core 11 kV cables

    • Historical Version
  3. BS 11/30214077 DC


    BS 7870-4.20. LV and MV polymeric insulated cables for use by distribution and generation utilities. Part 4. Specification for distribution cables with extruded insulation for rated voltages of 11 kV to 33 kV. Section 4.20. Three-core 11 kV cables

    • Historical Version
  4. BS 7870-4.20:1999


    LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables with extruded insulation for rated voltages of 11 kV and 33 kV-Three-core 11 kV cables-Three core 11 kV cables

    • Historical Version