About This Item

 

Full Description

BS EN 60404-15:2012+A1:2017 specifies a solenoid method, a magnetic moment method, a magnetic balance method and a permeability meter method for the determination of the relative magnetic permeability of feebly magnetic materials (including austenitic stainless steel). The magnetic balance and permeability meter methods are both comparison methods calibrated using reference materials to determine the value of the relative magnetic permeability of the test specimen. The relative magnetic permeability range for each of these methods is shown in Table 1. The methods given are for applied magnetic field strengths of between 5 kA/m and 100 kA/m.
Table 1 - Relative magnetic permeability ranges for the methods described
Measurement methodRelative magnetic permeability range
Solenoid1,003 to 2
Magnetic moment1,003 to 1,2
Magnetic balance1,003 to 5
Permeability meter1,003 to 2


NOTE 1 The relative magnetic permeability range given for the magnetic balance method covers the inserts provided with a typical instrument. These can only be assessed at values for which calibrated reference materials exist.

NOTE 2 For a relative magnetic permeability larger than 2, a reference material cannot be calibrated using this written standard. A note of this is given in the test report explaining that the values measured using the magnetic balance are for indication only.

The solenoid method is the reference method. The magnetic moment method described is used mainly for the measurement of the relative magnetic permeability of mass standards.

Two comparator methods used by industry are described. These can be calibrated using reference materials for which the relative magnetic permeability has been determined using the reference method. When suitable, the magnetic moment method can also be used. The dimensions of the reference material need to be given careful consideration when determining the uncertainty in the calibration value due to self-demagnetization effects. See Annex A for more information on correcting for self-demagnetization.


Cross References:
IEC 60050
ISO/IEC Guide 98-3:2008
GUM:1995
OIML R111-1:2004
EN 12163
EN 10088-1


Incorporates the following:
Amendment, March 2017. Amends and replaces BS EN 60404-15:2012
 

Document History

  1. BS EN 60404-15:2012+A1:2017

    👀 currently
    viewing


    Magnetic materials-Methods for the determination of the relative magnetic permeability of feebly magnetic materials

    • Most Recent
  2. BS EN 60404-15:2012


    Magnetic materials. Methods for the determination of the relative magnetic permeability of feebly magnetic materials

    • Historical Version
  3. BS 11/30217430 DC


    BS EN 60404-15. Magnetic materials. Part 15. Methods for the determination of the relative magnetic permeability of feebly magnetic materials

    • Historical Version
  4. BS 5884:1999


    Magnetic materials. Methods for the determination of the relative magnetic permeability of feebly magnetic materials

    • Historical Version
  5. BS 5884:1987


    Methods for determination of relative magnetic permeability of feebly magnetic materials

    • Historical Version
  6. BS 5884:1980


    Methods of test for determination of d.c. magnetic properties of magnetic materials

    • Historical Version