BS EN ISO 10703:2015 specifies a method for the simultaneous determination of the activity concentration of various radionuclides emitting gamma rays with energies 40 keV < E < 2 MeV in water samples, by gamma-ray spectrometry using germanium detectors with high energy resolution in combination with a multichannel analyser.

NOTE The determination of the activity concentration of radionuclides emitting gamma rays with energy below 40 keV and above 2 MeV is also possible within the scope of this International Standard, provided both the calibration of the measuring system and the shielding are adapted to this purpose.


This International Standard includes the procedures for energy calibration, determination of the energy dependent sensitivity of the measuring system, the analysis of the spectra and the determination of the activity concentration of the various radionuclides in the sample studied. It is only applicable to homogeneous samples. Samples with activities typically between 1 Bq and 104 Bq can be measured as such, i.e. without dilution or concentration of the sample or special (electronic) devices.

Depending on different factors, such as the energy of the gamma rays and the emission probability per nuclear disintegration, the size and geometry of the sample and the detector, the shielding, the counting time and other experimental parameters, the sample should be concentrated by evaporation when activities below about 1 Bq have to be measured. Also, when the activity is considerably higher than 104 Bq, the sample should be either diluted or an aliquot of the sample should be taken or the source to detector distance should be increased, or a correction for pile-up effects should be applied.


Cross References:
ISO 31-9
ISO 3696
ISO 5667-1
ISO 5667-3
ISO 5667-14
ISO/IEC 17025
IEC 60973
IEC 61151
IEC 61452
ANSI N42 .14:1999
ASTM E181-98 (2003)
IEEE Std 325 (1996)
ISO 11929


All current amendments available at time of purchase are included with the purchase of this document.
 

Document History

  1. BS EN ISO 10703:2021


    Water quality. Gamma-ray emitting radionuclides. Test method using high resolution gamma-ray spectrometry

    • Most Recent
  2. BS EN ISO 10703:2015

    👀 currently
    viewing


    Water quality. Determination of the activity concentration of radionuclides. Method by high resolution gamma-ray spectrometry

    • Historical Version