Electrical Equipment for Measurement, Control, and Laboratory Use; Part 2: Particular Requirements for Hand-Held Current Clamps for Electrical Measurement and Test

UL 61010B-2-032

1 Scope and object

This clause of part 1 is applicable, except as follows:

1.1 Scope

Replace the text by the following:This International Standard applies to hand-held and hand-manipulated CURRENT CLAMPS. These CURRENT CLAMPS are for use in the measurement of current without interruption of the current path of the circuit in which it is measured. They may be stand-alone CURRENT CLAMPS which are themselves within the scope of part 1, or accessories to other equipment within the scope of part 1.This standard does not apply to current transformers or current transducers intended for fixed installations.

1.4 Environmental conditions

Replace the seventh dash by the following:- primary input circuits with transient overvoltages according to INSTALLATION CATEGORIES (OVERVOLTAGE CATEGORIES) I, II, III and IV (see annex j).
 

Document History

  1. UL 61010-1


    Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 1: General Requirements

    • Most Recent
  2. UL 61010-1


    Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 1: General Requirements (Includes Revisions 1 and 2, from 2005 and 2008)

    • Historical Version
  3. UL 61010B-2-032

    👀 currently
    viewing


    Standard for Electrical Equipment for Measurement, Control, and Laboratory Use; Part 2: Particular Requirements for Hand-Held Current Clamps for Electrical Measurement and Test

    • Historical Version
  4. UL 61010B-2-031


    Electrical Equipment for Measurement, Control, and Laboratory Use; Part 2: Particular Requirements for Hand-Held Probe Assemblies for Electrical Measurement and Test

    • Historical Version
  5. UL 61010B-1


    Electrical Measuring and Test Equipment; Part 1: General Requirements

    • Historical Version
  6. UL 61010A-2-020


    Standard for Electrical Equipment for Laboratory Use; Part 2: Particular Requirements for Laboratory Centrifuges

    • Historical Version
  7. UL 61010A-2-042


    Electrical Equipment for Laboratory Use; Part 2: Particular Requirements for Autoclaves and Sterilizers Using Toxic Gas for the Treatment of Medical Materials, and for Laboratory Processes

    • Historical Version
  8. UL 61010C-1


    Process Control Equipment

    • Historical Version
  9. UL 61010A-2-051


    Stamdard for Electric Equipment for Laboboratory Use; Part 2-051: Particular Requirements for Laboratory Equipment for M

    • Historical Version
  10. UL 61010A-2-041


    Electrical Equipment for Laboratory Use; Part 2: Particular Requirements for Autoclaves Using Steam for the Treatment of Medical Materials and for Laboratory Processes

    • Historical Version
  11. UL 61010A-2-010


    Electrical Equipment for Laboratory Use: Part 2: Particular Requirements for Laboratory Equipment for the Heating of Materials

    • Historical Version
  12. UL 61010A-1


    Electrical Equipment for Laboratory Use; Part 1: General Requirements

    • Historical Version