Available Formats
- Options
- Availability
- Priced From ( in USD )
-
Available Formats
-
- Secure PDF 🔒
- Immediate download
-
$350.52Members pay $262.89
- Add to Cart
-
- Printed Edition
- Ships in 1-2 business days
-
$350.52Members pay $262.89
- Add to Cart
-
- Printed Edition + PDF
- Immediate download
-
$473.71Members pay $355.28
- Add to Cart
Customers Who Bought This Also Bought
-
BS EN 10244-2:2023
Priced From $190.50 -
BS EN IEC 60332-3-24:2018
Priced From $190.50 -
BS 8573:2012
Priced From $309.88 -
BS EN 60332-1-2:2004+A12:2020
Priced From $190.50
About This Item
Full Description
NOTE 1 Other thermosetting insulated, armoured cables for voltages of 600/1 000 V and 1 900/3 300 V can be found in BS 5467, but these do not have low levels of emission of smoke and corrosive products under exposure to fire.
This British Standard is applicable to cables for use in fixed installations in industrial areas, buildings or similar applications.
This British Standard specifies requirements for the following types of cables:
- 600/1 000 V cables, wire armoured and oversheathed having single-core, two-, three-, four- and five-core stranded copper conductor;
- 600/1 000 V multicore auxiliary cables, wire armoured, and oversheathed, stranded copper conductor; and
- 1 900/3 300 V cables, wire armoured and oversheathed, having single-core or three-core stranded copper conductor.
NOTE 2 Limitation on the temperature of the cables may be imposed in situations where they might be touched or where they could touch other materials.
NOTE 3 Annex A gives a guide to the use and installation of cables, Annex B gives armour wire tests, Annex C gives a compatibility test, Annex D gives an abrasion resistance test, Annex E gives an insulation resistance constant test on oversheath, Annex F gives the resistance of conductor and armour, Annex G gives the gross cross-sectional area of armour, Annex H gives a test for shrinkage of oversheath on cable, Annex I gives guidance on type tests and Annex J gives the standard United Kingdom reference codes.
Cross References:
BS 7655-1.2
BS 7655-1.3
BS 7655-6.1
BS EN 10244-2:2009
BS EN 50363-5
BS EN 50395
BS EN 50396
BS EN 60228
BS EN 60229
BS EN 60332-1-2:2004+A1:2015
BS EN 60332-3-24:2009
BS EN 60754-1
BS EN 60811-401
BS EN 60811-501
BS EN 60811-502
BS EN 61034-2
BS EN 62230
BS EN ISO 6892-1
IEC 60050-461
BS 5467
BS 7671:2008+A3:2015
BS 8512
BS 8573:2012
BS EN 50262
BS EN 50393
BS EN 60079-14
BS EN 61914
BS EN 62275
BS EN 62444
IEC 60183
Electricity Safety, Quality and Continuity Regulations
2002
Replaces BS 6724:1997+A3:2008 which remains current
All current amendments available at time of purchase are included with the purchase of this document.
Document History
-
BS 6724:2016
viewing
Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification- Most Recent
-
BS 6724:1997+A3:2008
Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V, having low emission of smoke and corrosive gases when affected by fire- Historical Version
-
BS 6724:1997
Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V, having low emission of smoke and corrosive gases when affected by fire- Historical Version