About This Item
Full Description
This British Standard is applicable to cables for use in fixed installations in industrial areas, buildings or similar applications, where maintenance of power supply during a fire is required for a defined period of time.
This British Standard specifies requirements for the following types of cables:
- wire armoured and oversheathed cables with two-, three-, four- or five-cores, and with stranded copper conductor;
- multicore auxiliary cables, wire armoured and oversheathed, with stranded copper conductor.
This British Standard is applicable to cables that are designed for a maximum sustained conductor temperature of 90 °C and for a maximum short-circuit conductor temperature of 250 °C (for a maximum of 5 s).
NOTE 1 Limitation on the temperature of the cables might be imposed in situations where they may be touched or where they could touch other materials.
NOTE 2 Annex A gives the guide to use, Annex B gives armour wire tests, Annex C gives compatibility test, Annex D gives abrasion test, Annex E gives insulation resistance constant test on oversheath, Annex F gives resistance of conductor and armour, Annex G gives gross cross-sectional area of armour, Annex H gives a test for shrinkage of oversheath, Annex I gives the fire resistance test for category F2 - additional provisions for cables with a diameter over 20 mm, and Annex J gives notes on type tests.
Cross References:
BS 6387
BS 7655-1.2
BS 7655-1.3
BS 7655-6.1
BS 7671
BS 8491
BS EN 10244-2:2009
BS EN 50363-5
BS EN 50395
BS EN 50396
BS EN 60228
BS EN 60229
BS EN 60332-1-2:2004
BS EN 60332-3-24:2009
BS EN 60754-1
BS EN 60811-501
BS EN 60811-502
BS EN 61034-2
BS EN 62230
IEC 60050-461
BS 5099
BS 7846:2009
BS 8512
BS 8519:2010
BS 8573:2012
BS EN 50265-2-1
BS EN 50266-2-4
BS EN 50356
BS EN 50393
BS EN 60079-14
BS EN 61914
BS EN 62275
BS EN 62444
IEC 60183
Replaces BS 7846:2009 which remains current.
All current amendments available at time of purchase are included with the purchase of this document.
Document History
-
BS 7846:2015
viewing
Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification- Most Recent
-
BS 7846:2009
Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1000 V, having low emission of smoke and corrosive gases when affected by fire. Specification- Historical Version
-
BS 09/30199575 DC
BS 7846. Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V, having low emission of smoke and corrosive gases when affected by fire. Specification- Historical Version
-
BS 7846:2000
Electric cables. 600/1000 V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire- Historical Version
-
BS 7846:1996
Specification for 600/1000 V armoured fire-resistant electric cables having low emission of smoke and corrosive gases when affected by fire- Historical Version