Full Description
Where the equipment is required to meet other environmental conditions, for example, protection against ingress of water and resistance to corrosion, additional methods of protection may be necessary. The method used should not adversely affect the integrity of the enclosure.
The requirements of BS EN 60079-14:2008 apply only to the use of equipment under normal or near normal atmospheric conditions. For other conditions, additional precautions may be necessary. For example, most flammable materials and many materials which are normally regarded as non-flammable might burn vigorously under conditions of oxygen enrichment.
Other precautions might also be necessary in the use of equipment under conditions of extreme temperature and pressure. Such precautions are beyond the scope of this standard. These requirements are in addition to the requirements for installations in non-hazardous areas.
BS EN 60079-14:2008 applies to all electrical equipment including fixed, portable, transportable and personal, and installations, permanent or temporary.
It applies to installations at all voltages.
BS EN 60079-14:2008 does not apply to
- electrical installations in mines susceptible to firedamp; NOTE This standard may apply to electrical installations in mines where explosive gas atmospheres other than firedamp may be formed and to electrical installations in the surface installation of mines.
-inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing);
- rooms used for medical purposes;
- electrical installations in areas where the hazard is due to hybrid mixtures of combustible dust and explosive gas, vapour or mist.
BS EN 60079-14:2008 does not take into account of any risk due to an emission of flammable or toxic gas from the dust.
Cross References:
IEC 60034-1
IEC 60034-5
IEC 60050-826
IEC 60060-1
IEC 60079
IEC 60079-0
IEC 60079-1
IEC 60079-2
IEC 60079-5
IEC 60079-6
IEC 60079-7
IEC 60079-11
IEC/TR 60079-13
IEC 60079-15
IEC/TR 60079-16
IEC 60079-18
IEC 60079-19
IEC 60079-25
IEC 60079-26
IEC 60079-27
IEC 60079-28
IEC 60079-29-1
IEC 60079-29-2
IEC 60079-31
IEC 60243-1
IEC 60332-1-2
IEC 60364
IEC 60364-4-41
IEC 60529
IEC 60950
IEC 61010-1
IEC 61241
IEC 61241-0
IEC 61241-1
IEC 61241-2-1
IEC 61241-4
IEC 61241-10
IEC 61241-11
IEC 61285
IEC 61558-2-6
IEC 62305-3
ISO 10807
EN 60034-1:2004
EN 60034-5:2001
CENELEC HD 588.1 S1:1991
EN 60079
EN 60079-0:2006
EN 60079-1:2007
EN 60079-2:2007
EN 60079-5:2007
EN 60079-6:2007
EN 60079-7:2007
EN 60079-11:2007
EN 60079-15:2005
EN 60079-18:2004
EN 60079-18:2004/Corrigendum:2006
EN 60079-19:2007
EN 60079-25:2004
EN 60079-25:2004/Corrigendum:2006
EN 60079-26:2007
EN 60079-27:2008
EN 60079-28:2007
EN 60079-29-1 2007
EN 60079-29-2:2007
EN 60079-29-2:2007/Corrigendum:2007
EN 60079-31
EN 60243-1:1998
EN 60332-1-2:2004
CENELEC HD 60364
CENELEC HD 384
CENELEC HD 60364-4-41:2007
CENELEC HD 60364-4-41:2007/Corrigendum:2007
EN 60529:1991
EN 60529:1991/Corrigendum:1993
EN 60950
EN 61010-1:2001
EN 61010-1:2001/Corrigendum:2002
EN 61241
EN 61241-0 2006
EN 61241-1:2004
EN 61241-1:2004/Corrigendum:2006
EN 61241-4:2006
EN 61241-10:2004
EN 61241-11:2006
EN 61285:2004
EN 61558-2-6:1997
EN 62305-3:2006
EN 62305-3:2006/Corrigendum:2008
EN ISO 10807:1996
IEC/TS 60034-17
IEC/TS 60034-25
IEC 60050-426
IEC 60332-2-2
IEC 60332-3
IEC 60614-2-1
IEC 60614-2-5
IEC 60742
IEC 60755
IEC 61008-1
IEC 61010-1
IEC 61024-1
CENELEC/TR 50427
CENELEC/TR 50404
CLC/TS 60034-17:2004
CLC/TS 60034-25:2005
EN 60332-2-2:2004
EN 60742:1995
EN 61558
EN 61008-1:2004
EN 61010-1:2001
EN 62305-3:2006
All current amendments available at time of purchase are included with the purchase of this document.
Document History
-
BS EN 60079-14:2014
Explosive atmospheres-Electrical installations design, selection and erection- Most Recent
-
BS 12/30269297 DC
BS EN 60079-14. Explosive atmospheres. Electrical installations design , selection and erection- Historical Version
-
BS EN 60079-14:2008
viewing
Explosive atmospheres-Electrical installations design, selection and erection- Historical Version
-
BS EN 60079-17:2007
Explosive atmospheres-Electrical installations inspection and maintenance- Historical Version
-
BS EN 61241-0:2006
Electrical apparatus for use in the presence of combustible dust-General requirements- Historical Version
-
BS EN 60079-0:2006
Electrical apparatus for explosive gas atmospheres-General requirements- Historical Version
-
BS EN 60079-2:2004
Electrical apparatus for explosive gas atmospheres-Pressurized enclosures "p"- Historical Version
-
BS EN 50020:2002
Electrical apparatus for potentially explosive atmospheres. Intrinsic safety 'i'- Historical Version
-
BS 05/30138005 DC
IEC 60079-14 ED 4. Electrical apparatus for explosive gas atmospheres. Part 14. Electrical installations in hazardous areas (other than mines)- Historical Version
-
BS EN 61241-17:2005
Electrical apparatus for use in the presence of combustible dust-Inspection and maintenance of electrical installations in hazardous areas (other than mines)- Historical Version
-
BS EN 61241-14:2004
Electrical apparatus for use in the presence of combustible dust-Selection and installation- Historical Version
-
BS EN 60079-0:2004
Electrical apparatus for explosive gas atmospheres-General requirements- Historical Version
-
BS EN 60079-14:2003
Electrical apparatus for explosive gas atmospheres-Electrical installations in hazardous areas (other than mines)- Historical Version
-
BS EN 60079-17:2003
Electrical apparatus for explosive gas atmospheres-Inspection and maintenance of electrical installations in hazardous areas (other than mines)- Historical Version
-
BS EN 50281-1-2:1999
Electrical apparatus for use in the presence of combustible dust. Electrical apparatus protected by enclosures-Selection, installation and maintenance- Historical Version
-
BS EN 50281-1-1:1999
Electrical apparatus for use in the presence of combustible dust. Electrical apparatus protected by enclosures-Construction and testing- Historical Version
-
BS EN 50016:2002
Electrical apparatus for potentially explosive atmospheres. Pressurized apparatus "p"- Historical Version
-
BS EN 60335-2-36:2000
Specification for safety of household and similar electrical appliances-Particular requirements for commercial electric cooking ranges, ovens, hobs and hob elements- Historical Version
-
BS EN 60335-2-36:1995
Specification for safety of household and similar electrical appliances. Particular requirements-Commercial electric cooking ranges, ovens, hobs and hob elements- Historical Version
-
BS EN 50014:1998
Electrical apparatus for potentially explosive atmospheres. General requirements- Historical Version
-
BS EN 60079-14:1997
Electrical apparatus for explosive gas atmospheres-Electrical installations in hazardous areas (other than mines)- Historical Version
-
BS EN 60079-17:1997
Electrical apparatus for explosive gas atmospheres-Inspection and maintenance of electrical installations in hazardous areas (other than mines)- Historical Version
-
BS EN 50016:1996
Electrical apparatus for potentially explosive atmospheres. Pressurized apparatus 'p'- Historical Version
-
BS EN 50016-1996:1996
Electrical Apparatus for Potentially Explosive Atmospheres - Pressurized Apparatus "p"- Historical Version
-
BS EN 50020:1995
Electrical apparatus for potentially explosive atmospheres. Intrinsic safety 'i'- Historical Version
-
BS EN 50014:1993
Electrical apparatus for potentially explosive atmospheres. General requirements- Historical Version
-
BS 3456-202-202.36:1990
Specification for safety of household and similar electrical appliances. Particular requirements-Commercial electric ranges, ovens and hob elements- Historical Version
-
BS 3456-102-102.36:1989
Specification for safety of household and similar electrical appliances. Particular requirements-Commercial electric ranges, ovens and hob elements- Historical Version
-
BS 5345-1:1989
Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture)-General recommendations- Historical Version
-
BS 6467-2:1988
Electrical apparatus with protection by enclosure for use in the presence of combustible dusts-Guide to selection, installation and maintenance- Historical Version
-
BS CP 1003-3:1967
Electrical apparatus and associated equipment for use in explosive atmospheres of gas or vapour other than mining applications-Division 2 areas- Historical Version
-
BS CP 1003-2:1966
Electrical apparatus and associated equipment for use in explosive atmospheres of gas or vapour other than mining applications-Methods of meeting the explosion hazard other than by the use of flameproof or intrinsically-safe electrical equipment- Historical Version
-
BS 6467-1:1985
Electrical apparatus with protection by enclosure for use in the presence of combustible dusts-Specification for apparatus- Historical Version
-
BS 5345-5:1983
Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture)-Installation and maintenance requirements for electrical apparatus protected by pressurization 'p' and by continuous dilution, and for pressurized rooms- Historical Version
-
BS 5345-1:1976
Code of practice for the selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture)-Basic requirements for all Parts of the code- Historical Version
-
BS 5345-8:1980
Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture)-Installation and maintenance requirements for electrical apparatus with type of protection 's'. Special protection- Historical Version
-
BS 5784-1:1979
Safety of electrical commercial catering equipment-Specification for ranges, ovens and hob elements- Historical Version
-
BS 5345-7:1979
Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture)-Installation and maintenance requirements for electrical apparatus with type of protection N- Historical Version
-
BS 5345-3:1979
Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture)-Installation and maintenance requirements for electrical apparatus with type of protection 'd'. Flameproof enclosure- Historical Version
-
BS 5345-6:1978
Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture)-Recommendations for type of protection 'e'. Increased safety- Historical Version
-
BS 5345-4:1977
Code of practice for selection, installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture)-Installation and maintenance requirements for electrical apparatus with type of protection 'i'. Intrinsically safe electrical apparatus and systems- Historical Version
-
BS 5501-1:1977
Electrical apparatus for potentially explosive atmospheres-General requirements- Historical Version
-
BS 5501-3:1977
Electrical apparatus for potentially explosive atmospheres-Pressurized apparatus 'p'- Historical Version
-
BS 5501-7:1977
Electrical apparatus for potentially explosive atmospheres-Intrinsic safety 'i'- Historical Version
-
BS CP 1003-1:1964
Electrical apparatus and associated equipment for use in explosive atmospheres of gas or vapour other than mining applications-Choice, installation and maintenance of flameproof and intrinsically-safe equipment- Historical Version
-
BS 4683-1:1971
Specification for electrical apparatus for explosive atmospheres-Classification of maximum surface temperatures- Historical Version
-
BS 4137:1967
Guide to the selection of electrical equipment for use in division 2 areas- Historical Version
-
BS 1259:1958
Intrinsically safe electrical apparatus and circuits for use in explosive atmospheres- Historical Version