-
-
Available Formats
- Options
- Availability
- Priced From ( in USD )
-
Available Formats
-
- Secure PDF 🔒
- Immediate download
- $190.50
- Add to Cart
-
- Printed Edition
- Ships in 1-2 business days
- $190.50
- Add to Cart
-
- Printed Edition + PDF
- Immediate download
- $257.81
- Add to Cart
Customers Who Bought This Also Bought
-
BS EN 60318-3:2015
Priced From $190.50 -
BS EN 60645-5:2005
Priced From $264.16 -
BS EN ISO 389-9:2009
Priced From $190.50 -
BS EN ISO 22868:2021
Priced From $350.52
About This Item
Full Description
It states the information in a form suitable for direct application to the calibration of audiometers, that is, in terms of the reference equivalent threshold sound pressure levels of generic supra-aural earphones specified in 4.2, measured on an ear simulator complying with IEC 60318-1 and in terms of modelspecific data given in two additional tables for the IEC 60318-3 acoustic coupler and the IEC 60318-1 ear simulator, respectively.
The data are based on an assessment of the information available from the various standardizing laboratories responsible for audiometric standards and from scientific publications.
Cross References:
IEC 60318-3
IEC 60318-1:2009
ANSI/ASA S3.6-2010
ISO 389-9
ISO 7029
All current amendments available at time of purchase are included with the purchase of this document.
Document History
-
BS EN ISO 389-1:2018
viewing
Acoustics. Reference zero for the calibration of audiometric equipment-Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones- Most Recent
-
BS EN ISO 389-1:2000
Acoustics. Reference zero for the calibration of audiometric equipment-Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones- Historical Version
-
BS EN ISO 389:1997
Acoustics. Standard reference zero for the calibration of pure tone air conduction audiometers- Historical Version
-
BS 2497-5:1988
Standard reference zero for the calibration of pure tone air conduction audiometers-Specification for a standard reference zero using an acoustic coupler complying with BS 4668- Historical Version
-
BS 2497-7:1988
Standard reference zero for the calibration of pure tone air conduction audiometers-Specification for a standard reference zero at frequencies intermediate between those given in Parts 5 and 6 of BS 2497- Historical Version
-
BS 2497-6:1988
Acoustics. Reference zero for the calibration of audiometric equipment-Specification for a standard reference zero using an artificial ear complying with BS 4669- Historical Version
-
BS 2497-3:1972
Specification for a reference zero for the calibration of pure-tone audiometers-Data for a wide-band artificial ear complying with BS 4669- Historical Version
-
BS 2497-2:1969
Specification for a reference zero for the calibration of pure-tone audiometers-Data for certain earphones used in commercial practice- Historical Version
-
BS 2497-1:1968
Specification for a reference zero for the calibration of pure-tone audiometers-Data for earphone coupler combinations maintained at certain standardizing laboratories- Historical Version