Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
    • Secure PDF 🔒
    • 👥
    • Immediate download
    • $24.00
    • Add to Cart
    • Printed Edition
    • Ships in 1-2 business days
    • $24.00
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

Many Southwest Florida utilities use the Floridan Aquifer System (FAS) as the source of raw water for their drinking water production. Over the last decade several utilities have turned to this source instead of shallow, freshwater aquifers, which suffered from reducing water levels and degraded source-water quality. In South Florida the FAS contains large quantities of brackish groundwater with good and uniform quality, is protected from human influences by overlying confining layers and is therefore the preferred source in areas of limited fresh groundwater supply. The City of Cape Coral was one of the first cities to convert to the FAS. Due to rapid population growth, the City has begun a sizeable Utility Extension and Facility Expansion Program to meet these needs. While keeping pace with this rapid growth, the City will also increase the percentage of population served with drinking water via an accelerated Utility Extension Program. Currently 71% of the population is served and this will increase from 85% in 2015 to close to 100% in 2020. Cape Coral is a pre-platted community that relies on domestic self-supply in areas not served by the Utility system. The potable demand is anticipated to increase from the current 14 MGD to 29 MGD in 2015. The expansion of the existing Southwest Reverse Osmosis Water Treatment Plant (SWRO WTP) from 15 to 18 MGD is currently underway, to meet short-term needs. In addition, the construction of the new North Reverse Osmosis Water Treatment Plant (NRO WTP) with an ultimate capacity of 36 MGD, to meet the longterm demands, has commenced. The first phase of the NRO WTP has been designed for a capacity of 12 MGD and will be operational in early 2009. The second phase providing an additional 12 MGD of treatment capacity needs to be operational in 2015. Following the experience at the SWRO WTP and supported by groundwater modeling, the raw water quality is expected to deteriorate over time. The main contributor to this is that a large percentage of the recharge to the production aquifer is through leakage from underlying, more saline aquifers. The raw water deterioration requires special design considerations for the NRO WTP. This paper presents a summary of the hydrogeology of the FAS, explains the background and concept of changing aquifer conditions over time and will present the features included in the design of the NRO WTP to cope with the deteriorating raw water quality. Many water utilities in Southwest Florida using brackish groundwater are dealing with the same issue. Therefore this case study is a typical representation of the challenge of the Region's water supply. Includes 13 references, tables, figures.