Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
    • Secure PDF 🔒
    • 👥
    • Immediate download
    • $398.78
    • Add to Cart
    • Printed Edition
    • Ships in 1-2 business days
    • $398.78
    • Add to Cart
    • Printed Edition + PDF
    • Immediate download
    • $538.48
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

BS EN 61010-031:2015 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below, and their related accessories. These probe assemblies are for direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment.
  • Type A: low-voltage and high-voltage, non-attenuating probe assemblies. Non-attenuating probe assemblies that are RATED for direct connection to voltages exceeding 30 V r.m.s., 42,4 V peak, or 60 V d.c., but not exceeding 63 kV. They do not incorporate components which are intended to provide a voltage divider function or a signal conditioning function, but they may contain non-attenuating components such as fuses (see Figure 1.)
  • Type B: high-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies that are RATED for direct connection to secondary voltages exceeding 1 kV r.m.s. or 1,5 kV d.c. but not exceeding 63 kV r.m.s. or d.c. The divider function may be carried out wholly within the probe assembly, or partly within the test or measurement equipment to be used with the probe assembly (see Figure 2).
  • Type C: low-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies for direct connection to voltages not exceeding 1 kV r.m.s. or 1,5 kV d.c. The signal conditioning function may be carried out wholly within the probe assembly, or partly within the test or measurement equipment intended to be used with the probe assembly (see Figure 3).
  • Type D: low-voltage attenuating, non-attenuating or other signal conditioning probe assemblies, that are RATED for direct connection only to voltages not exceeding 30 V r.m.s., or 42,4 V peak, or 60 V d.c., and are suitable for currents exceeding 8 A (see Figure 4).

Cross References:
IEC 60027
EN 60027
IEC 60529
IEC 61010-1:2010
EN 61010-1:2010
IEC 61180-1:1992
EN 61180-1:1994
IEC 61180-2
EN 61180-2
IEC Guide 104
ISO/IEC Guide 51
IEC 60065
EN 60065
IEC 60270
EN 60270
IEC 60364-4-44
HD 60634-4-44
IEC 60664-1
EN 60664-1
IEC 60664-3:2003
EN 60664-3:2003
IEC 60664-3:2003/A1:2010
EN 60664-3:2003/A1:2010
IEC 60664-4:2005
EN 60664-4:2006
IEC 60990
EN 60990
IEC 61010
EN 61010
IEC 61032:1997
EN 61032:1998
IEC 60050-151:2001
IEC 60050-195:1998
IEC 60417
ISO 7000


Replaces BS EN 61010-031:2002+A1:2008 which remains current

All current amendments available at time of purchase are included with the purchase of this document.
 

Document History

  1. BS EN IEC 61010-031:2023


    Safety requirements for electrical equipment for measurement, control, and laboratory use-Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement

    • Most Recent
  2. BS EN 61010-031:2015+A1:2021


    Safety requirements for electrical equipment for measurement, control and laboratory use-Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement

    • Historical Version
  3. BS EN 61010-031:2015

    👀 currently
    viewing


    Safety requirements for electrical equipment for measurement, control and laboratory use-Safety requirements for hand-held probe assemblies for electrical measurement and test

    • Historical Version
  4. BS 11/30244390 DC


    BS EN 61010-031. Safety requirements for hand-held probe assemblies for electrical measurement and test. Part 031. Safety requirements for hand-held probe assemblies for electrical measurement and test

    • Historical Version
  5. BS EN 61010-031:2002+A1:2008


    Safety requirements for electrical equipment for measurement, control and laboratory use-Safety requirements for hand-held probe assemblies for electrical measurement and test

    • Historical Version
  6. BS EN 61010-031:2002


    Safety requirements for electrical equipment for measurement, control and laboratory use. Safety requirements for hand-held probe assemblies for electrical measurement and test

    • Historical Version
  7. BS EN 61010-2-031:1995


    Safety requirements for electrical equipment for measurement, control and laboratory use-Particular requirements for hand-held probe assemblies for electrical measurement and test

    • Historical Version